electrical equipment

Electric heating boiler

发布时间:2018-08-06 Source: Cangzhou Surong Electric BoilerRelease time: 2018-08-06

Electric heating boilerDomestic heating boiler

Electric heating boiler power price:

Electric heating boiler product name Common power Heating area Electric heating boiler price

Resistance electric boiler

Resistance electric boiler

Resistance electric boiler 2-500KW 20-5000 square meters 0317-4855545

PTC electric boiler

PTC electric boiler

PTC electric boiler 2-10KW 20-110 square meters 0317-4855545

Electromagnetic heating boiler

Induction heating stove

Electromagnetic heating boiler 2-10KW 20-110 square meters 0317-4855545

The electric heating boiler is mainly used for electric heating equipment used in the heating industry. The power of this product is generally from 2KW-400KW, ranging in size, and can be used in homes, offices, engineering and other places.

Functional description of electric heating boiler

1. Constant temperature control If the working temperature is not set after the power is turned on, the system works at the default parameter of 50 ° C; if the working temperature is set, it runs according to the set operation.
After starting up, the controller detects that the heating temperature is 8 ° C lower than the set temperature, presses the set position, turns on the heating tube, cuts off the power when the heating temperature is higher than the set temperature, and stops heating. The temperature slowly decreases to 8 ° C below the set temperature, and the heating tube is turned on again to achieve constant temperature. |

2. Plumbing cycle When the default heating temperature of the system is higher than 50 ℃ after the heating pipe is turned on, the circulating pump is turned on to perform the plumbing cycle; when the temperature is lower than 40 ℃, the circulating pump is turned off to stop the plumbing cycle.

3. Timing function The system defaults to turn on the day at 10:00 and turn off the time at 14:00 every day. The boot time at night is 18:00 and the shutdown time is 6 am the next morning.
According to the user's needs, you can adjust the daily on and off time by pressing the "Setting key" and "Up / down key". After the time is set, the timer function is activated.

4. High temperature protection When the dry burn protector detects that the temperature is higher than 95 ° C, immediately cut off the power to the heating tube.

5. Leakage protection When the leakage current is detected to be greater than 15mA, immediately cut off the power supply to prevent electric shock. The display shows a fault code and a warning prompt. After the fault is removed, the controller can restart to work normally.

6. Anti-freeze function When the controller is powered on, when the anti-freeze function is activated, when the temperature is detected to be lower than 3 ° C, the heater starts to heat; when the temperature is detected to rise to 8 ° C, the heater stops heating.

7. Memory function There is a memory function for various set parameters. You don't need to set it again after turning off the power. After the Beijing time is set, it can run as usual after power-off. You do not need to adjust the time again after power-on.


Previous: Floor heating boiler

Next post: Household electric heating boiler